Showing posts with label Production Support Issues. Show all posts
Showing posts with label Production Support Issues. Show all posts

Error calling number range object


Solution

1. Note down the InfoCube and Dimension name.

2. Go to T-Code: RSRV --> All Elementary Tests --> Transactional Data then double click on “Comparison of Number Range of a Dimension and Maximum DIMID” --> then click the same on the right side pane --> Mention the InfoCube name and Dimension name, click on Transfer button --> Click on top Correct Error.

 
 

PSA error record

Reason

It may happen some times that the incoming data to BW is having some incorrect format, or few records have few incorrect entries. 



Solution

1. Go to details tab, find its packet number and its record number.


2.  Click on PSA icon in monitor and select the error Data Packet


3. Double click on error record and edit it to the correct value, Select Save.

Now update from PSA to target by selecting the option Start update immediately. 
 

Time stamp error

Reason
  • The “Time Stamp” Error occurs when the Transfer Rules or Transfer Structure are internally inactive in the system.
  • They can also occur whenever the DataSources are changed on the R/3 side or the DataMarts are changed in BW side. In that case, the Transfer Rules is showing active status when checked. But they are actually not, it happens because the time stamp between the DataSource and the Transfer Rules are different.



Solution 

1. Go to RSA1 --> Source system --> Replicate DataSource



2. Run the program RS_TRANSTRU_ACTIVATE_ALL



3. Mention Source System and InfoSource and then execute.



Now the Transfer Structure will be automatically activated then proceed with the reload, it will get success now.

 
 